Find my proA heat pump that won't turn on in New Hampshire is most often tripped by the cold itself, not a broken part. If ice has built up on the outdoor unit and it hasn't had a chance to defrost, the system can lock out rather than run and risk damage. A tripped breaker or a blown fuse does the same thing, and either one is common after a hard freeze or a power blip, which happens more than once in a New Hampshire winter. Check the thermostat too. If it's set to a mode the system doesn't recognize, or the batteries are dead, nothing downstream gets the signal to start. If the outdoor unit is buried in snow or the breaker won't stay reset, that's not something to force. It points to a problem inside the unit, a stuck defrost control or a failed component, that needs a contractor to look at before you lose heat on a cold night.

No ice on the coil, no frost on the lines. The unit cycles on, runs its defrost when it needs to, and shuts off clean. Mulch and a shrub nearby are fine as long as nothing blocks the airflow around the cabinet.

Dust and grime built up like this over time, and that buildup chokes the airflow the unit needs to defrost itself in the cold. Weathering alone won't stop it from running, but a coil this dirty makes a lockout far more likely on a hard winter night.

If your heat pump is paired with oil backup and the pump quits, that backup kicks in to keep the rooms warm. Oil will cover you, but you're paying for heat twice this winter: once in the service call you need, and once in the fuel you're burning while the pump sits dark. With electricity priced the way it is here, the pump going down also means losing the cheaper half of your heating setup right when you need it most.
Check the outdoor unit before you assume the worst. A cabinet packed with snow after a storm, or ice that's built up past what a normal defrost cycle clears, can be enough to stop it from starting. Clear what you can reach safely. If it still won't run, or the ice comes back fast, that points to something mechanical rather than the weather, and it's worth having someone look at it rather than waiting out the cold. Send the details through and a contractor who knows these systems will follow up, so you're not the one tracking down who's available.







A heat pump doesn't just kick on when the thermostat calls for heat. The control board checks the outdoor temperature and a sensor clipped to the outdoor coil before it lets the compressor run at all. That sensor is watching for ice. Once frost builds past a certain point on the coil, the board calls for a defrost cycle: the outdoor fan stops, the reversing valve switches the refrigerant flow, and the unit runs backward for a few minutes to melt the ice off before switching back to heating. If the reversing valve sticks, that switch never happens, and the cycle stalls wherever it left off. If the sensor never sends a clean signal, the board can't tell if the coil is clear, so it holds the unit off rather than let it run while iced over. On the coldest New Hampshire nights, some units go further and shift into a low ambient lockout, where the board decides it's too cold outside for the compressor to run safely and just waits. None of that is a malfunction by itself. It's the board doing what it's built to do with the information it has.


A heat pump that sits dead on a cold morning is not something to wait out. New Hampshire winters don't let up, and if oil is picking up the slack, the furnace is running longer and harder to cover for a system that should be carrying its share. That shows up on a power bill that's already steep here before you add in a furnace doing extra work. Every day it sits off is a day the house is running on one leg instead of two, and the fix for a lockout or a stuck defrost cycle is usually not complicated once someone is actually looking at the unit. You don't have to track down who does this kind of work or wait on hold to find out if they're taking calls. Send the request and let someone who knows this equipment take it from here. The house stays warm either way. The question is what it costs you while you wait.
When the outdoor unit locks out from cold, nothing is broken inside it. The board is just refusing to run the compressor until conditions change or someone resets it. That means the fix can be quick once a contractor gets eyes on it, but it also means the unit can lock out again the next cold snap if whatever caused it, iced coils, a stuck defrost cycle, isn't addressed. A reset without a look at why it tripped is a short-term answer.
Before anything else gets checked, the breaker is worth a look. A heat pump pulls a steady load every time it cycles, and in a hard freeze it can cycle more than usual trying to keep up. If a breaker trips, the unit has no power at all, no lights, no hum, nothing, and it will sit dead until someone flips it back. It's the simplest thing to rule out and the easiest to miss standing outside in the cold.
At 24.53 cents per kilowatt-hour, every hour your heat pump sits dead and the oil furnace carries the house instead costs you on two fronts: oil you're already burning, and a system you're still paying to keep plugged in. Getting the pump running again is what stops that bleed.
EIA-861 2025 statewide residential average
Thermostat calls for heat and sends power to the control board.
The board checks outdoor temperature and defrost sensor readings first.
If conditions are outside its range, the board blocks the compressor.
Cleared to run, the board energizes the contactor and starts the compressor.

Summer here isn't the problem season for most of what this page covers, but it's worth knowing what your heat pump is doing those months. Averaged across New Hampshire, the summer dew point runs 59°F, which is on the comfortable side as humidity goes. Your heat pump isn't working hard to pull moisture out of the air the way it would further south. That's easier duty on the compressor than winter asks of it. It also means if your system is struggling to cool on a mild, dry day, humidity isn't the cause. Something else is off, and it's worth having looked at before winter puts real load on the same unit.
NASA POWER T2MDEW county cells weighted by homes


A heat pump that stays dead on a cold morning almost always comes down to one of two things. Either the outdoor unit has iced over and locked itself out until it can defrost, or the board has decided the temperature outside is too low for the compressor to run safely. Neither one means something inside has failed. A dirty coil or blocked fins can cause the same kind of stop, starving the unit of air it needs before cold ever enters the picture at all.
While the pump sits idle, the oil furnace picks up the load, and that's heat you're paying for twice: once through the oil already burning, and once through the power still feeding a system that isn't running. New Hampshire winters don't leave room to wait that out for long.
None of this usually means a new part or a long repair. A contractor can often clear the lockout, reset the board, or clean the coil in a single visit, and the pump goes back to carrying its share of the house the same day someone looks at it.
What's left after that is simple. Send the form, and the work of finding who to call stops being yours. Someone who handles this for a living takes it from there, and the only thing left on your end is a warm house again.